Installing and connecting a 3-phase rail system: step by step

Zwarte 3-fase rail aan het plafond met LED railspots die een eettafel en een schilderij verlichten

A track system is the most flexible way to light a space. You hang one track from the ceiling and then click the spotlights into it wherever you want them. If you change the layout, you simply move the spotlights. In this guide, I’ll show you step by step how to plan, install and commission my 3-phase track system: from the first track to the last spotlight.

L1L2L33 groepen in één rail · 230V~

How it works at a glance

  1. Plan the route, the spotlights and which spotlights switch together.
  2. Turn off the power at the circuit breaker and check.
  3. Mount the tracks on the ceiling and join them with connectors.
  4. Have a certified installer connect the power supply head.
  5. Fit end caps, click the spotlights into place and test each circuit.

⚡ Caution, 230 volts. Unlike a plug-in LED strip, this track system connects directly to the mains. You can mount the tracks and position the spotlights yourself, but always have a certified installer connect the power supply head. Switch off the circuit at the circuit breaker before carrying out any work.

Jump straight to:

The track system components

Everything is designed for a 3-phase (4-wire) track at 230V~ and is available in white and black. Choose all the components in the same colour for a sleek look.

1.5-metre trackaluminium, the base that the spotlights click into
Power supply headat the start, connects the system to 230V~
Mini straight I-connectortwo tracks straight, compact and barely visible
Straight I-connectortwo tracks firmly in a straight line, current flows through
L-shaped 90° connectoran angled corner, for example along two walls
T-connectora branch off a straight line
X-cross connectorfour tracks at one point, for a cross or grid
End capneatly and safely finishes every open end

You order the black track and the white track of 1.5 metres separately. You order the power supply head, connectors and end caps with your tracks; the easiest way is with the track system configurator, which calculates exactly what you need. Tracks and connectors are IP20: for dry indoor spaces only. They come with a 2-year warranty.

🪜 Ladder🔩 Drill🧱 Wall plugs and screws for your ceiling🪛 Screwdriver🔦 Voltage tester🔌 Installation cable to the power supply head

Three circuits in one track

The term 3-phase says it all: there are three conductors in the track, L1, L2 and L3, with a common neutral (N). You place each spotlight on one of these three circuits. This allows you to switch the spotlights above a counter separately from the spotlights along the wall, while they are hanging in the same track. If you want to switch everything on and off at the same time, put all the spotlights on the same circuit.

L1L2L3Ndoorsnede van de rail
L1 · group 1, for example the spotlights above the table
L2 · group 2, for example the spotlights along the wall
L3 · group 3, for example the spotlights on a cabinet or painting
N, the common neutral

How it all connects

MeterkastSchakelaar(s)VoedingskopRailsRailspotsgroep · 230V~per circuitbegin van de rail+ verbindersop L1, L2 of L3aansluiten door een erkend installateur

For each connected track system, you need one power supply head. The current flows through the connectors to all the tracks attached to it. How many circuits you can actually switch separately depends on how many phases the installer connects to the power supply head: one, two or all three.

Which layout suits your space?

With the connectors, you can create almost any shape from individual tracks. The rule is simple: one power supply head at the start, a connector at every junction and an end cap at every open end. Below you can see four commonly used layouts, with what you need for each shape in addition to the tracks.

Straight line1 power supply head · I-connector per additional track · 1 end cap
L-shape1 power supply head · 1 L-shaped connector · 1 end cap
T-shape1 power supply head · 1 T-connector · 2 end caps
Cross1 power supply head · 1 X-cross connector · 3 end caps
power supply head connector end cap

Prefer not to count yourself? Draw your space in the track system designer or put the whole thing together in the track system configurator. It will automatically add the power supply head, connectors and end caps.

Step-by-step guide: how to install the track system

1

Plan the route and the spotlights

Draw the route of the tracks on the ceiling, for example with a pencil and a ruler. Mark where corners, branches and crossings will be, and where the connection for the power supply head is. Determine how many spotlights you will place, which ones will be on the same circuit together and add up their wattage, so the installer can adjust the power supply accordingly.

Total wattage calculation example

20W20W20W20W20W20W=120W6 spots × 20W
2

Turn off the power and check

Turn off the circuit for the room at the circuit breaker. Then check with a voltage tester that there really is no more voltage on the connection wires. Only then should you start drilling and installing.

meterkastspanningzoeker: geen spanning = lampje uit✓ veilig werken
3

Mount the tracks on the ceiling

Hold the track against the ceiling along the drawn line and mark the mounting holes. Drill the holes, insert the wall plugs and screw the track into place. Use wall plugs and screws that suit your ceiling, as a concrete ceiling requires something different from plasterboard. Check that the tracks are perfectly in line before tightening everything completely.

4

Join the tracks with connectors

Slide the connector into the ends of both tracks and secure it with the screws. For a straight line, choose the mini or the regular I-connector, for a 90° corner the L-shaped connector, for a branch the T-connector and for a cross the X-cross connector. Push the connector all the way in: only then will the current flow properly to the next track.

✓ helemaal erin, schroefjes vast
5

The power supply head: leave it to the installer

The power supply head goes at the start of the track. The installer connects the cable according to the markings in the power supply head: the neutral (N) and one, two or three phases (L1, L2, L3), depending on how many circuits you want to switch separately. Then he slides the power supply head into the track and secures it. Discuss your plan from step 1 with him beforehand, then he will know exactly which spotlights go on which circuit.

voedingskopL1L2L3N⚠ 230V · alleen door een erkend installateur
6

Finish the ends with end caps

Every open end of a track gets an end cap. It looks neater and the end is safely enclosed. Count them again: for a T-shape you need two, for a cross three.

eindkap op elk open uiteinde
7

Click the spotlights into place, aim them and test

Click the track spotlights into the desired positions on the track, turn the adapter straight so that it locks, and choose a circuit for each spotlight; you can find out exactly how to do this in the spotlight's manual. Then switch the circuit back on at the fuse box and test each circuit separately. Finally, aim each spotlight: the light cover tilts up to 90° and rotates 350°.

klik · vergrendeldkantelt tot 90°draait 350°

Which track spotlight should you choose?

All track spotlights fit the same 3-phase track and are available in 10, 20, 30 and 40W, in warm white 3000K and cool white 4000K, in white and black. They have a single COB light source, a 5-year warranty and are not dimmable. The main difference lies in the beam and the version.

24°24°: focused accent lightingNarrow beam to highlight products, art or a table. There are two colour rendering options: CRI>90 and CRI>80. In the CRI>90 version, the driver, a Philips or Osram, is in a separate power supply box at the track adapter, so that the light cover itself remains slim.
36°36°: focused and slightly widerA balance between accent lighting and a wider beam, with CRI>90. The driver is in a slim housing directly on the track adapter, so that the spotlight looks sleek and compact. There is also a version with a premium driver.
Power 24° · 3000K 24° · 4000K 36° · 3000K 36° · 4000K
10W 950 lm 1,000 lm 1,000 lm 1,050 lm
20W 1,900 lm 2,000 lm 2,000 lm 2,100 lm
30W 2,850 lm 3,000 lm 3,000 lm 3,150 lm
40W 3,800 lm 4,000 lm 4,000 lm 4,200 lm

View all versions in the LED track spotlights. Not sure whether to choose warm white or cool white? With the Light colour in your room tool, you can see the difference immediately.

Not working as expected?

What do you see? Probable cause Solution
Nothing is lit at all The circuit is switched off, or the power supply head is not properly connected or is loose in the track Check the circuit and have the installer check the power supply head
One group of spotlights remains unlit The circuit for those spotlights is not connected or is switched off Check the connection in the power supply head and the circuit selection of the spotlights
Spotlights after a connector remain unlit The connector is not fully inserted into both tracks Power is off, slide the connector completely in and tighten the screws
Spotlight is loose in the track The adapter is not turned straight or locked properly Replace the spotlight and lock the adapter completely

Working safely and maintenance

  • Always switch off the power before installing, moving a spotlight or connecting anything.
  • Leave the connection to 230V, maintenance and repairs to a professional, also if a cable is damaged.
  • Calculate the total power of all spotlights in advance and adjust the power supply accordingly.
  • Only clean tracks and spotlights with a dry or slightly damp cloth, with the power switched off.

This guide is intended as advice; always follow the product manual if in doubt.

Installation manual as PDF

Take the manual with you to the installer or print it out for the stairs: 3-phase track system installation manual (PDF).

Frequently asked questions

Can I connect the track system myself?

You can install the tracks and place the spotlights yourself. Always have a certified installer connect the power supply head to 230V.

How many power supply heads do I need?

One per continuous track system. The power runs through the connectors to all the tracks attached to it.

Can I switch spotlights separately?

Yes. The track has three circuits (L1, L2 and L3). You choose a circuit for each spotlight, and the installer connects one, two or three phases, depending on how many groups you want to switch separately.

Are the track spotlights dimmable?

No, the track spotlights are not dimmable. With the three circuits, you can switch groups of spotlights on and off separately.

Can I move spotlights later?

Yes, that is exactly the advantage of a track. Switch off the power, unlock the adapter, click the spotlight into the new position and lock it again.

Can the track system be used in the bathroom or outdoors?

No. Tracks, connectors, power supply head and end caps are IP20 and therefore only suitable for dry indoor spaces.

Need help with your design?

Send me a message via the contact form with a sketch or photo of your space, and I will help you think about the route and the number of spotlights. I am happy to calculate larger projects for you in a quote.

Bas van LEDPLANET.NL